Loading...
Name |
Two in one lightning arrester |
Three in one lightning arrester |
|||||||||||||
Explain |
Video+power |
100M network+power supply |
1000M network+power supply |
Video+data+power |
Network+data+power |
||||||||||
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
|
Insertion loss |
0.3dB |
||||||||||||||
Response time |
<0.1ns |
||||||||||||||
Working temperature zone |
-60℃~+80℃ |
||||||||||||||
Nominal discharge current |
5Ka |
||||||||||||||
Maximum discharge current |
10Ka |
||||||||||||||
Video/network parameters |
|||||||||||||||
working voltage Un |
5V |
||||||||||||||
Limiting voltage Uc |
8V |
||||||||||||||
Protection level Up |
15V |
||||||||||||||
Transmission speed Vs |
20Mbps |
100Mbps |
1000Mbps |
20Mbps |
100Mbps |
||||||||||
Parameters of power supply |
|||||||||||||||
Working voltage Un |
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
12V |
24V |
220V |
Limiting voltage Uc |
18V |
47V |
470V |
18V |
47V |
470V |
18V |
47V |
470V |
18V |
47V |
470V |
18V |
47V |
470V |
Protection level Up |
60V |
90V |
900V |
60V |
90V |
900V |
60V |
90V |
900V |
60V |
90V |
900V |
60V |
90V |
900V |
Data part parameters |
|||||||||||||||
Working voltage Un |
- |
5V |
|||||||||||||
Limiting voltage Uc |
8V |
||||||||||||||
Protection level Up |
15V |
||||||||||||||
Transmission speed Vs |
- |
||||||||||||||
Overall dimensions |
102mm×67mm×29mm/104mm×57mm×32mm |
Functional classification |
Voltage classification |
Model |
Functional classification |
Voltage classification |
Model |
100M network+power two in one lightning protector (enhanced) |
12V |
TL-EV2/12 |
100M network+power two in one lightning arrester (ordinary type) |
12V |
TL-NP/12 |
24V |
TL-EV2/24 |
24V |
TL-NP/24 |
||
220V |
TL-EV2/220 |
220V |
TL-NP/220 |
||
Video+power two in one lightning protector (enhanced) |
12V |
TL-SV2/12 |
Video+power two in one lightning protector (ordinary type) |
12V |
TL-VP/12 |
24V |
TL-SV2/24 |
24V |
TL-VP/24 |
||
220V |
TL-SV2/220 |
220V |
TL-VP/220 |
||
Video+data+power three in one lightning protector (enhanced) |
12V |
TL-SV3/12 |
Video+data+power three in one lightning protector |
12V |
TL-VDP/ 12 |
24V |
TL-SV3/24 |
24V |
TL-VDP/ 24 |
||
220V |
TL-SV3/220 |
220V |
TL-VDP/ 220 |
||
Network+data+power three in one lightning protector (enhanced) |
12V |
TL-EV3/12 |
1000M network+power two in one lightning protector (enhanced) |
12V |
TL-KEV 2/ 12 |
24V |
TL-EV3/24 |
24V |
TL-KEV 2/ 24 |
||
220V |
TL-EV3/220 |
220V |
TL-KEV 2/ 220 |
The lightning arrester shall be inspected regularly during its use. In case of failure, it shall be repaired or replaced in time to ensure equipment safety.